Results 1 - 20 de 28
Filter
1.
Rev. bras. saúde ocup ; 48: e23, 2023. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1529968

ABSTRACT

Resumo Objetivo: descrever as características dos casos de COVID-19 relacionados ao trabalho notificados no Brasil, em 2020 e 2021. Métodos: estudo descritivo com dados do Sistema de Informação de Agravos de Notificação (Sinan). Foram calculadas as frequências de casos segundo variáveis sociodemográficas, ocupacionais e epidemiológicas. Resultados: nos anos de 2020 e 2021, foram notificados 36.110 e 34.508 casos de COVID-19 relacionados ao trabalho, respectivamente. Considerando os dois anos, houve maior frequência de notificações de casos de indivíduos do sexo feminino (65,1%), de raça/cor da pele preta e parda (42,1%) e na faixa etária de 30 a 39 anos (32,8%). A região Nordeste concentrou 28,4% dos casos notificados. Houve emissão de comunicação de acidente de trabalho (CAT) em 13,5% dos casos notificados, com elevada proporção de informação ausente para essa variável (42,6%). As categorias ocupacionais com mais notificações foram técnicos de nível médio (31,0%) e profissionais de ciências e artes (23,7%). A evolução cura foi a mais frequente nos dois anos analisados (2020: 72,0%; 2021: 68,0%). Conclusão: os resultados apontam para um perfil de casos com predominância de mulheres, trabalhadores(as) de raça/cor da pele preta e parda e com idades entre 30 e 39 anos. Destaca-se, ainda, a baixa completude das notificações.


Abstract Objective: to describe the characteristics of work-related COVID-19 cases reported in Brazil between 2020 and 2021. Methods: descriptive study using secondary data collected from the Brazilian Notifiable Diseases Information System (SINAN). Frequency was calculated according to sociodemographic, occupational and epidemiological variables. Results: in the years 2020 and 2021, a total of 36,110 and 34,508 work-related COVID-19 cases were reported, respectively. Considering both years, there was a higher frequency of notifications for female individuals (65.1%), black and mixed-race (42.1%), from the age group 30 to 39 years (32.8%). The Northeast region accounted for 28.4% of the reported cases. Work Accident Report (CAT) was issued in 13.5% of the reported cases, with a high percentage of missing information for this variable (42.6%). Middle-level technicians (31.0%) and professionals in sciences and the arts (23.7%) accounted for most notifications. Cure was the most prevalent outcome in both years (2020: 72.0%; 2021: 68.0%). Conclusion: the results point to a predominant profile of cases among women, black and mixed-race individuals, and those aged between 30 and 39 years. The low completeness of notifications is noteworthy.

2.
Braz. dent. j ; 33(4): 47-53, July-Aug. 2022. tab, graf
Article in Portuguese | LILACS-Express | LILACS, BBO | ID: biblio-1394087

ABSTRACT

Resumo O presente estudo teve como objetivo realizar dois tratamentos térmicos diferentes em instrumentos de NiTi austenítico ProFile e comparar o desempenho mecânico de instrumentos originais e tratados termicamente. O tratamento térmico dos instrumentos ProFile (tamanho de ponta 25 e conicidade 0.06) foi realizado em um forno em atmosfera de argônio usando uma taxa de aquecimento de 10°C/min. Após atingir as temperaturas programadas de 450 ºC ou 500 ºC o sistema permaneceu em temperatura constante por 10 minutos; seguido de resfriamento em água à temperatura ambiente. Em seguida; os três grupos de instrumentos (n=30 por grupo) foram comparados quanto à fadiga cíclica (n=10 por grupo); flexão (n=10 por grupo) e resistência à flambagem (n=10 por grupo). Após testes de fadiga cíclica; um microscópio eletrônico de varredura foi utilizado para analisar as superfícies de fratura e observar o modo de fratura. A análise estatística foi realizada por meio dos testes de One-way ANOVA e teste de Student-Newman-Keuls; com erro de tipo alfa fixado em 0.05. Coloração amarelada e azulada foi observada nos instrumentos ProFile após tratamentos térmicos a 450 ºC ou 500 ºC; respectivamente. Os instrumentos ProFile originais apresentaram menor fadiga cíclica e maior resistência à flexão e flambagem (P<0.05). Em contraste; os instrumentos ProFile azulados (tratados termicamente a 500°C) apresentaram maior fadiga cíclica e menor resistência à flexão e flambagem (P>0.05). Pode-se concluir que os diferentes tratamentos térmicos realizados nos instrumentos ProFile aumentaram sua resistência à fadiga cíclica e melhoraram a flexibilidade e resistência à flambagem.


Abstract The present study aimed to perform two different heat-treatments in an austenitic NiTi ProFile instrument and to compare the mechanical performance of original and heat-treated instruments. Heat treatment of ProFile (tip size 25 and 0.06 taper) instruments were carried out in a furnace in argon atmosphere using a heating rate of 10° C/min. After reaching the programmed temperatures of 450 ºC or 500 ºC the system remained at a constant temperature for 10 minutes; followed by cooling in water at room temperature. Afterwards; the three groups (n=30 per group) of instruments were compared regarding their cyclic fatigue (n=10 per group); bending (n=10 per group); and buckling resistance (n=10 per group). After cyclic fatigue tests; a scanning electron microscope was used to analyze the fracture surfaces and observe the fracture mode. Statistical analysis was performed using One-way ANOVA and Student-Newman-Keuls test; with an alpha type error set at 0.05. Yellowish and blueish coloration was observed in the ProFile instruments after 450 ºC or 500 ºC heat treatments; respectively. Conventional ProFile instruments showed the lower cyclic fatigue; and the higher bending and buckling resistance (P<0.05). In contrast; yellowish ProFile instruments (heat treated at 500° C) showed the higher cyclic fatigue; and the lower bending and buckling resistance (P>0.05). It can be concluded that the different heat treatments performed on ProFile instruments increased its cyclic fatigue resistance and improved the flexibility and buckling resistance.

3.
Dent. press endod ; 11(3): 52-57, Sept-Dec.2021. Tab, Ilus
Article in English | LILACS | ID: biblio-1379356

ABSTRACT

Objetivo: O objetivo do presente estudo foi avaliar a influência do pré-alargamento coronário na resistência à fadiga cíclica de dois instrumentos reciprocantes tratados termicamente. Métodos: 20 instrumentos Reciproc Blue (R25 Blue) e 20 instrumentos X1 Blue (X1) foram utilizados para instrumentar blocos de resina simulando um molar superior com três canais radiculares. Os dentes foram divididos em quatro grupos (n=10), de acordo com o instrumento e com a técnica de instrumentação utilizada: grupos R25 e X1 - instrumentação com R25 Blue (25/0.08) ou X1 Blue (25/0.06), respectivamente, sem alargamento prévio; e grupos R25 ou X1 + pré-alargamento cervical - pré-alargamento com os instrumentos ProTaper Universal SX e S1 antes da instrumentação com R25 Blue ou X1. Os instrumentos foram testados com relação à fadiga cíclica utilizando-se um canal simulado de aço inoxidável com ângulo de curvatura de 86 graus e raio de curvatura de 6 mm. Os instrumentos foram acionados utilizando-se o movimento "RECIPROC ALL" do motor endodôntico (VDW) e o tempo de instrumentação até a fratura do instrumento foi contabilizado. Os resultados foram analisados pelo teste t de Student (p<0,05). Resultados: Os instrumentos X1 apresentaram maior resistência à fadiga cíclica do que R25 Blue em ambas as condições testadas (p<0,05). Não houve diferença entre os grupos com e sem pré-alargamento coronário para os instrumentos R25 Blue e X1 (p>0,05). Conclusão: O instrumento X1 Blue apresentou maior resistência à fadiga cíclica do que o Reciproc Blue. O pré-alargamento coronário não foi capaz de aumentar a resistência à fratura por fadiga cíclica dos instrumentos testados (AU).


Objective: The aim of this study was to evaluate the influence of cervical pre-flaring on the cyclic fatigue resistance of two heat-treated reciprocating instruments. Methods: 20 Reciproc Blue (R25 Blue) instruments e 20 X1 Blue File (X1) were used to instrument resin blocks simulating an upper molar with 3 root canals. The specimens were divided into four groups (n=10) according the instrument and type of instrumentation used: R25 and X1 groups: root canal preparation with R25 Blue (25/0.08) ou X1 Blue (25/0.06), without cervical pre-flaring; R25 or X1 + cervical pre-flaring- pre-flaring with ProTaper Universal SX e S1 before instrumentation with R25 Blue or X1 blue. After instrumentation the instruments were tested for cyclic fatigue using a simulated stainless steel root canal with 86 degree bending angle and 6 mm bending radius. The instruments were triggered using the "RECIPROC ALL" motion of a reciprocating endodontic motor (VDW) and the instrumentation time until instrument fracture was accounted. Results were analyzed by Students t-test (p<0.05). Results: Statistical analysis showed that the X1 Blue showed higher resistance to cyclic fatigue than the R25 Blue under both conditions tested (p<0.05). There were no differences between the groups with and without coronary pre-flaring for the R25 Blue and X1 Blue (p<0.05). Conclusion: X1 Blue showed higher resistance to cyclic fatigue than the R25 Blue. The cervical pre-flaring did not increased the resistance to cyclic fatigue fracture of the tested instruments (AU)


Subject(s)
Stainless Steel , Root Canal Preparation/instrumentation , Flexural Strength , Hot Temperature , Simulation Exercise , Fatigue
4.
Rev. Rede cuid. saúde ; 15(2): [28-43], dez. 2021.
Article in English | LILACS | ID: biblio-1349492

ABSTRACT

Purpose: The aim of the present study was to verify the knowledge of health professionals being educated in the Medical and Dentistry courses about oral cancer, specifically Oral Squamous Cell Carcinoma (OSCC), in view of this being the most prevalent type of cancer of the head and neck. Methods: A questionnaire contained objective questions was applied with the aim of evaluating knowledge about some aspects of OSCC. Students in the clinical cycle of the Course in Medicine and Course in Dentistry participated. Both groups were in the 5th and 8th semesters at the Campuses 1 (C1) and 2 (C2). A total of 454 questionnaires were answered and evaluated, distributed as follows: 301 and 153 from the C1 and C2, respectively. Results: The results show that the students from Medicine of the C1 and C2 were observed to be "Regular" (40.67%) and "Insufficient" (44.58%), respectively. For the course in Dentistry of C1 and C2, the prevalent response was "Good" for courses, 52.67% and 46.38%, respectively. Conclusion: The results revealed an inadequate level of knowledge of OSCC. Despite the knowledge is transmitted, changes are necessary to allow the students more time in clinical practice to reptai knowledge.


Objetivo: O objetivo do presente estudo foi verificar o conhecimento dos profissionais de saúde formados nos cursos de Medicina e Odontologia sobre câncer bucal, especificamente o Carcinoma de Células Escamosas Bucais (CCEB), tendo em vista que este é o tipo de câncer de cabeça e pescoço mais prevalente. Metodologia: Um questionário contendo perguntas objetivas foi aplicado com o objetivo de avaliar o conhecimento sobre alguns aspectos do CCEB. Participaram os alunos do ciclo clínico dos cursos de Medicina e Odontologia. Ambos os grupos estavam no 5º e 8º semestres nos campi 1 (C1) e 2 (C2). Foram respondidos e avaliados 454 questionários, distribuídos da seguinte forma: 301 e 153 do C1 e C2, respectivamente. Resultados: Os resultados mostram que os estudantes de Medicina dos C1 e C2 foram observados como "Regular" (40,67%) e "Insuficiente" (44,58%), respectivamente. Para o curso de Odontologia dos C1 e C2, a resposta predominante foi "boa" para os cursos, 52,67% e 46,38%, respectivamente. Conclusão: Os resultados revelaram um nível inadequado de conhecimento da CCEB. Apesar do conhecimento ser transmitido, são necessárias mudanças para permitir que os alunos tenham mais tempo na prática clínica para reter conhecimento.


Subject(s)
Humans , Male , Female , Mouth Neoplasms , Dentistry , Workforce , Squamous Cell Carcinoma of Head and Neck , Medicine
5.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1385796

ABSTRACT

RESUMEN: La irrigación del sistema de conductos radiculares con soluciones antibacterianas es considerada una parte esencial de la preparación químico-mecánica. Varios factores influyen en la eficacia de la irrigación del conducto radicular, incluyendo tamaño de la preparación apical y ensanchamiento, distancia de penetración de la aguja con respecto al ápice, flujo y volumen de sustancia de irrigante, dimensión de las agujas y la presencia de curvatura del conducto radicular. El tamaño de la preparación apical y la conicidad afectan el recambio del irrigante, el esfuerzo de corte en las paredes del conducto radicular y la presión en el foramen apical. La colocación de la punta de la aguja más cerca del ápice, permite un recambio de la solución más eficiente, resultando una mejor limpieza y desinfección del conducto radicular. La velocidad del irrigante, al lado de la aguja, en las paredes del conducto opuestas y frente a la salida de la aguja es dependiente del diseño de la aguja. El patrón de flujo y recambio del irrigante de las agujas con extremo abierto es diferente al de las agujas cerradas y las que logran mejor recambio de irrigante en la parte apical del conducto radicular también conducen a un aumento de la presión media en el foramen apical, lo que indica un mayor riesgo de extrusión del irrigante hacia el tejido periapical. El objetivo de esta revisión a la literatura, es evaluar los diferentes diseños de agujas y su influencia en la irrigación del sistema de conductos radiculares.


ABSTRACT: Root canal irrigation with antibacterial solutions is considered an essential part of the chemical-mechanical preparation. Several factors influence the efficacy of root canal irrigation, including apical preparation size and taper, needle penetration distance from the apex, flow and volume of irrigant substance, dimension of the needles and the presence of curvature of the root canal. The apical preparation size and the taper affect irrigant replacement, shear stress on the root canal walls, and pressure on the apical foramen. Placing the tip of the needle closer to the apex, allows more efficient solution exchange, resulting in better cleaning and disinfection of the root canal. The velocity of the irrigant, next to the needle, on the opposite canal walls and in front of the needle outlet is dependent on the design of the needle. The flow and irrigant replacement pattern of open ended needles is different from needles with closed tip. The needles that achieve better irrigant exchange in the apical part of the root canal also lead to an increase in mean pressure in the apical foramen which indicates a greater risk of extrusion of the irrigant into the periapical tissue. The objective of this literature review is to evaluate the different needle designs and their influence on the root canal system irrigation.

6.
Dent. press endod ; 11(1): 40-45, Jan-Apr2021. Tab, Ilus
Article in English | LILACS | ID: biblio-1348171

ABSTRACT

Objetivo: Testar a hipótese nula de que a orientação das ranhuras superficiais não influencia na vida em fadiga de fios de níquel-titânio (NiTi). Material e Métodos: Segmentos de fio de NiTi (Moreli, Sorocaba/SP, Brasil) medindo 30mm e com diâmetro de 0,40mm foram utilizados. As ranhuras foram criadas em relação à direção longitudinal, em 45 e 90 graus. O fio foi analisado sob microscopia eletrônica de varredura e a rugosidade, quantificada por interferometria. O número de ciclos para a fratura (NCF) foi determinado pelo teste de flexão rotativa. Resultados: A rugosidade entre os grupos de 45 e 90 graus apresentou diferenças estatisticamente significativas (p<0,05). O grupo sem ranhuras apresentou o maior NCF (p<0,05). O grupo com ranhuras em 45 graus apresentou maior NCF, em comparação ao grupo com 90 graus (p<0,05). Conclusões: A direção das ranhuras possui influência na vida em fadiga dos fios de NiTi. O NCF aumenta com a redução do ângulo das ranhuras em relação ao longo eixo do fio, independentemente da profundidade das ranhuras (AU).


Objective: this study tested the null hypothesis that the surface grooves orientation does not influence the NiTi wire cyclic fatigue. Material and methods: Segments of NiTi wire (Moreli, Sorocaba, Brazil) measuring 30mm and with a 0.40mm of diameter were used. Grooves were created in the longitudinal direction, at 45 degrees and 90 degrees. The wire was analyzed with SEM and the roughness was quantified by interferometry. The number of cycles until fracture (NCF) was determined by the cyclic fatigue test. Results: the roughness between 45 and 90 degrees groups presented differences (p<0.05). The group without grooves presented the highest NCF (p<0.05). The group with 45 degrees grooves presented better NCF in comparison to the group with 90 degrees (p<0.05). Conclusions: the direction of the grooves influences the fatigue life. The NCF increases with the reduction of the angle of the grooves in relation to the long axis, regardless of the depth of the grooves (AU).


Subject(s)
Humans , Microscopy, Electron, Scanning , Dental Alloys , Fatigue , Interferometry
7.
Acta sci., Biol. sci ; 43: e58474, 2021. tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-1461015

ABSTRACT

Edible mushrooms have a number of medicinal properties and this study aimed to investigate the antimicrobial activity of Pleurotus eryngiiDPUA1816 in metabolic broths after being grown in submerged cultivation. Mycelial fragments of pure P. eryngiiculture was inoculated in sweet potato culture medium and incubated at 150 rpm for 15 days at 25°C. Pleurotuseryngiiwas also cultivated for 18 days under the same conditions, the mycelial biomass was separated by filtration for quantification. The supernatant was used in the diffusion test in agar and performed against Escherichia coliCCCD-E005, Staphylococcus aureus CCCD-S009, Pseudomonas aeruginosaCCCD-P004, Candida albicansCCCD-CC001, Candida parapsilosis CCCD-CC004 and Candida tropicalisCCCD-CC002. The samples showed no inhibitory activity against bacteria, however they showed some activity againstC. albicans(12.17 mm), C. parapsilosis(27.67 mm) and C. tropicalis(13.67 mm). After being cultivated for 18 days, P. eryngiiwas able to inhibit all yeasts after 12 days of culture, with an inhibition halo of 29.33 mm at 16 days against C. parapsilosis. This study demonstrates the antifungal potential filtered liquids from P.eryngiicultivated in purple-skinned sweet potato culture medium, which suggests the possibility of the use of this species by the pharmaceutical industry as a natural source of biological action.


Subject(s)
Anti-Infective Agents , Antifungal Agents , Pleurotus/physiology , Candida albicans , Candida parapsilosis , Candida tropicalis , Escherichia coli , Pseudomonas aeruginosa , Staphylococcus aureus
8.
Braz. oral res. (Online) ; 35: e021, 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1153624

ABSTRACT

Abstrac The aim of the present study was to evaluate the cyclic fatigue, torsional resistance and surface roughness of Reciproc R25 instruments in four different situations, namely as new instruments and as instruments tested after clinical preparation of one, two or three maxillary molars with four root canals. The total time required to perform each root canal preparation was recorded. Cyclic fatigue resistance was determined by the time to fracture using a customized testing device (n = 10 per group). The torsional test evaluated the torque and angle of rotation to failure according to ISO 3630-1 (n = 10 per group). The roughness of the working parts of new and used instruments was evaluated with a profilometer (n = 5 per group). Statistical analysis was performed using one-way ANOVA and Tukey's test. The level of significance was set at 5%. No fractures or deformations were observed after clinical use. Higher preparation time was needed during the third use of the instruments for all root canals (p < 0.05). There were no significant differences among the groups in regard to either cyclic fatigue or torsional resistance (p > 0.05). Regarding the roughness measurements, groove depth was higher on new and one- versus two- or three-maxillary-molar-prepared instruments (p < 0.05). It can be concluded that the clinical use of Reciproc instruments increased preparation time and decreased surface roughness. However, clinical use did not affect the cyclic fatigue or torsional resistance of the Reciproc instruments.


Subject(s)
Titanium , Root Canal Preparation , Stress, Mechanical , Materials Testing , Torque , Dental Instruments , Equipment Design
9.
Dent. press endod ; 9(3): 62-66, Sept-Dec.2019. Tab, Ilus
Article in English | LILACS | ID: biblio-1343879

ABSTRACT

Objetivo: o presente estudo teve como objetivo caracterizar as dimensões dos instrumentos Reciproc R25 e X1 Blue File, e dos cones de guta-percha da Mk Life R25, Reciproc R25 e DiaDent R25, para verificar qual cone de guta-percha se adapta melhor no preparo dos instrumentos. Métodos: dez instrumentos Reciproc R25 25/0,08v e X1Blue File 25/0,06; e dez cones de guta-percha Dia- Dent R25, Mk Life R25 e Reciproc R25 foram utilizados. As imagens foram obtidas através de uma lupa estereoscópica com uma câmera digital acoplada. As medidas foram obtidas através do programa TS View. Os diâmetros dos instrumentos e dos cones de guta-percha foram determinados em D0 até D9, com intervalos de medidas de 1,0 mm; e a conicidade foi calculada adotando-se os diâmetros D8 e D1. Os resultados obtidos foram submetidos à análise estatística utilizando o programa Primer of biostatistics versão 6.0. Resultados: apesar da maior conicidade dos instrumentos X1Blue file (0,07mm/mm), não houve diferença estatisticamente significativa entre os instrumentos nos três primeiros milímetros (p > 0,05), o mesmo ocorreu para a conicidade dos cones (p > 0,05). Os cones de guta-percha apresentaram diferença estatisticamente significativa em todos os diâmetros aferidos (p < 0,05). Conclusão: os instrumentos e os cones de guta-percha atenderam à recomendação das respectivas normas ANSI/ADA. O cone de guta-percha que apresentou maior compatibilidade dimensional com os diâmetros dos instrumentos foi o MK life, e VDW foi o que apresentou maior desajuste (AU).


Objective: The aim of this study was to characterize the dimensions of the Reciproc R25 and X1 Blue File instruments and the gutta-percha points of Mk Life R25, Reciproc R25 and DiaDent R25 to verify which gutta-percha point better fits to the instruments preparation. Material and methods: Ten Reciproc R25 25/0.08v and X1Blue File 25/0.06 instruments; and ten DiaDent R25, Mk Life R25 and Reciproc R25 gutta-percha points were used. The images were obtained through a stereomicroscopic with a digital camera coupled. The measurements were obtained through the TS View program. The diameters of instruments and gutta-percha points were determined in D0 through D9 at 1.0 mm intervals, and the taper was calculated by adopting diameters D8 and D1. The results were submitted to statistical analysis using the program Primer of biostatistics version 6.0. Results: Despite the greater taper of the X1Blue file instruments (0.07mm /mm), there was no statistically significant difference between the instruments in the first 3 millimeters (p> 0.05), the same was observed for the tapers of the guta-percha points (p> 0.05). The gutta-percha points presented a statistically significant difference in all measured diameters (p <0.05). Conclusion: Gutta-percha points and instruments have met the recommendations of their respective ANSI/ADA standards. The gutta-percha point that presented greater dimensional compatibility with the diameters of the instruments was the MK life, and VDW presented the greatest mismatch (AU).


Subject(s)
Root Canal Filling Materials , Root Canal Obturation , Dental Instruments , Gutta-Percha
10.
Dent. press endod ; 9(2): 36-42, maio 2019. Ilus
Article in Portuguese | BBO, LILACS | ID: biblio-1024601

ABSTRACT

Objetivo: o objetivo do presente estudo foi avaliar a fadiga cíclica e torcional dos instrumentos WA1 e WaveOne Gold. Métodos: vinte instrumentos do sistema WA1 (25/0,07v) e vinte instrumentos do sistema WaveOne Gold (25/0,07v) foram utilizados. A resistência à fadiga cíclica foi testada, medindo o tempo até a fratura em um canal artificial curvo de aço inoxidável com ângulo de 80° e raio de curvatura de 3 mm (n = 10). O torque máximo e ângulo de rotação no momento da falha dos instrumentos (n = 10) foram medidos de acordo com a norma ISO 3630-1. A superfície de fratura de todos os fragmentos foi examinada com um microscópio eletrônico de varredura. Os resultados foram analisados estatisticamente usando o teste t de Student com um nível de significância de 5%. Resultados: não foram observadas diferenças na vida em fadiga cíclica dos instrumentos testados (p > 0,05). A força máxima de torção dos instrumentos WA1 foi menor do que os instrumentos WaveOne Gold (p < 0,05); entretanto, não foram observadas diferenças no ângulo máximo de rotação de ambos os sistemas (p > 0,05). A fotomicrografia eletrônica de varredura da superfície da fratura revelou características similares e típicas de fadiga cíclica e de falha por torção para os dois tipos de instrumentos. Conclusão: dentro dos resultados do presente estudo, pode-se concluir que os instrumentos WaveOne Gold e WA1 tiveram comportamento similar com relação à fadiga cíclica. No entanto, o instrumento WaveOne Gold apresentou maior deflexão angular à fratura por torção, em comparação aos instrumentos WA1 (AU).


Introduction: The aim of the present study was to evaluate the cyclic and torsional fatigue resistance of WA1 and WaveOne Gold instruments. Methods: Twenty instruments of the WA1 system (25/0.07v) and twenty instruments of the WaveOne Gold system (25/0.07v) were used. The cyclic fatigue resistance was tested by measuring the time to fracture in a stainless steel curved artificial canal with an angle of 80° and a radius of curvature of 3 mm (n = 10). The maximum torque and rotation angle at instrument failure (n = 10) were measured according to ISO 3630-1. The fracture surface of all the fragments was examined with a scanning electron microscope. The results were statistically analyzed using the student t-test with a significance level of 5%. Results: There were no differences in cyclic fatigue life of the tested instruments (P> 0.05). The maximum torsional force of the WA1 instruments was lower than the WaveOne Gold instruments (P <0.05); however, no differences were observed in the maximum rotation angle of both systems (P> 0.05). The scanning electron photomicrographs of the fracture surface revealed similar and typical characteristics of cyclic fatigue and torsional failure for the 2 types of instruments. Conclusion: Within the results of the present study, it can be concluded that WaveOne Gold and WA1 instruments had similar behavior regarding cyclic fatigue. However, WaveOne Gold instruments presented greater angular deflection to torsional fracture than WA1 instruments.


Subject(s)
Dental Instruments , Endodontics , Torsion, Mechanical , Fatigue
11.
Rev. Soc. Bras. Med. Trop ; 51(6): 843-847, Nov.-Dec. 2018. tab
Article in English | LILACS | ID: biblio-1041493

ABSTRACT

Abstract INTRODUCTION Peripheral blood of 400 dogs infected with Leishmania and Ehrlichia were analyzed using polymerase chain reaction (PCR), and clinical signs were characterized. METHODS PCR and parasitological tests were conducted. RESULTS PCR was positive for Leishmania in 84.75%, and parasitological tests showed that 63.25% and 31.75% were positive for Leishmania and Ehrlichia, respectively. All animals showed more than three clinical signs. PCR results were negative for Leishmania in 15.25% of the samples. CONCLUSIONS Conventional PCR of peripheral blood can be used for diagnosing canine visceral leishmaniasis in combination with other techniques, especially in uncertain cases that need species identification.


Subject(s)
Animals , Male , Female , Dogs , Ehrlichiosis/veterinary , Dog Diseases/diagnosis , Leishmaniasis, Visceral/veterinary , Brazil/epidemiology , Polymerase Chain Reaction , Sensitivity and Specificity , Ehrlichiosis/diagnosis , Ehrlichiosis/epidemiology , Endemic Diseases , Dog Diseases/epidemiology , Coinfection , Leishmaniasis, Visceral/diagnosis , Leishmaniasis, Visceral/epidemiology
12.
Rev. pesqui. cuid. fundam. (Online) ; 10(4): 1020-1025, out.-dez. 2018. tab, il
Article in English, Portuguese | LILACS, BDENF | ID: biblio-916071

ABSTRACT

Objetivo: Mensurar a variação do duplo-produto nos pacientes com infarto agudo do miocárdio submetidos ao banho de aspersão. Métodos: Pesquisa observacional realizada na Unidade Coronariana de um hospital de referência em cardiologia localizado na cidade do Rio de Janeiro. A amostragem deu-se por conveniência e teve como amostra os banhos de aspersão de pacientes adultos, ambos os sexos, com diagnóstico médico de infarto agudo do miocárdio com supradesnível ou sem supradesnível de segmento ST, e que tivessem indicação de banho de aspersão, fornecida pelo médico e enfermeiro responsáveis. Resultados: Houve aumento do valor médio do duplo-produto em todos os pacientes acompanhados, porém sem significância estatística. Conclusão: A indicação do banho de aspersão nesta amostra foi segura


Objective: To measure the variation of the double product in patients with acute myocardial infarction submitted to spray bath. Methods: Observational study, conducted in the Coronary Care Unit of a referral hospital in cardiology located in the city of Rio de Janeiro. Sampling was given for convenience and was to sample the spray baths adult patients, both sexes, with a diagnosis of AMI with elevation or non-ST segment elevation, and they had spray bath indication provided by the doctor and nurse responsible. Results: There was increase in the average value of the double product in all patients followed, but without statistical significance. Conclusion: The indication of the spray bath in this sample was safe


Objetivo: Medir la variación del doble producto en pacientes con infarto agudo de miocardio sometido a baño de aerosol. Métodos: Estudio observacional, realizado en la Unidad Coronaria de un hospital de referencia en cardiología ubicada en la ciudad de Río de Janeiro. El muestreo se da por conveniencia y era para probar los baños de aspersión pacientes adultos, de ambos sexos, con diagnóstico de IAM con elevación o sin elevación del segmento ST, y que había indicación de baño de aerosol proporcionada por el médico y la enfermera responsable. Resultados: No hubo aumento en el valor medio de la doble producto en todos los pacientes siguió, pero sin significación estadística. Conclusión: La indicación del baño de pulverización en esta muestra era seguro


Subject(s)
Humans , Male , Female , Adult , Baths/nursing , Myocardial Infarction/nursing , Nursing Care , Baths/instrumentation , Baths/statistics & numerical data , Brazil , Cardiovascular Nursing
13.
RGO (Porto Alegre) ; 66(2): 111-116, Apr.-June 2018. tab, graf
Article in English | LILACS | ID: biblio-956201

ABSTRACT

ABSTRACT Objective: This study compared the fatigue behavior of endodontic instruments manufactured with conventional NiTi alloy electropolishing, RaCe (FKG Dentaire, LaChauxdeFonds, Switzerland), with instruments manufactured with NiTi CM ​​Wire subjected to thermomechanical treatment, in the manufacturing process, HyFlex CM (Coltène Whaledent, Cuyahoga Falls, Ohio, USA), both with similar geometry and dimensions in order to determine the influence of the manufacturing process in the fatigue resistance. Methods: The methodoly consisted of twenty HyFlex CM and RaCe instruments with D0 0.25 mm, taper 0.06 mm / mm, 25 mm length, both with triangular cross section. The fracture resistance was evaluated by static fatigue test, using a stainless artificial canal with 5mm of radius (86°), recording the time and calculating the number of cycles until fracture occurs (NCF). For statistical analysis the Student t test was used The fractured instruments surface was analyzed by SEM. Results: The NCF was significantly higher for HyFlex CM instruments in comparison with RaCe files (P˂0.05) being 1336% more resistant to fatigue. The analysis of the fractured surface by SEM showed ductile-kind morphological characteristics for both instruments and the absence of plastic deformation. Conclusion: HyFlex CM instruments present higher values ​​of NCF. Thus, it can be concluded that the thermal treatment to which these instruments with CM Wire alloy are submitted makes them more resistant to fracture than Race instruments manufactured with conventional NiTi alloy electropolishing.


RESUMO Objetivo: Este estudo comparou a vida em fadiga de instrumentos endodônticos fabricados com a liga de NiTi convencional com eletropolimento de superfície, RaCe (FKG Dentaire, LaChauxdeFonds, Suiça), com instrumentos fabricados com a liga de NiTi CM Wire, submetidos a tratamento termomecânico, no processo de fabricação, HyFlex CM (Coltene Whaledent, Cuyahoga Falls, Ohio, EUA), ambos com geometria e dimensões semelhantes, visando determinar a influência do processo de fabricação das ligas e do acabamento superficial na resistência à fadiga. Métodos: Foram utilizados vinte instrumentos HyFlex CM e RaCe com D0 0,25mm, conicidade 0,06mm/mm, 25mm de comprimento, ambos com seção transversal triangular. A resistência à fratura foi avaliada através de teste estático de fadiga ciclica, utilizando um canal artificial em aço-inoxidável com 5mm de raio (86°), sendo registrado o tempo e calculado o número de ciclos para ocorrer a fratura (NCF). Para análise estatística empregou-se o teste t de Student. As superfícies de fratura dos instrumentos foram analisadas em MEV. Resultados: O NCF foi significativamente maior para os instrumentos HyFlex CM em comparação com as limas RaCe (p˂0,05), sendo 1336% mais resistentes à fadiga. A análise das superfícies fraturadas em MEV revelou características morfológicas do tipo dúctil para ambos os instrumentos e ausência de deformação plástica. Conclusão: Os instrumentos HyFlex CM apresentaram valores mais elevados de NCF. Deste modo, pode-se concluir que o tratamento térmico a qual estes instrumentos com a liga CM Wire foram submetidos os torna mais resistentes à fratura do que os instrumentos Race, fabricados com a liga de NiTi convencional com eletropolimento.

14.
Dent. press endod ; 8(1): 23-28, Apr-Jun. 2018. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-883676

ABSTRACT

Objetivo: esse estudo comparou a flexibilidade de instrumentos de níquel-titânio rotatórios com diferentes conicidades, em diferentes diâmetros da haste helicoidal cônica (D3 e D6). Métodos: trinta instrumentos RaCe (FKG, La Chaux-de Fonds, Suíça), #40 (D0 = 40), com 25 mm de comprimento, foram divididos em três grupos (n = 10), de acordo com sua conicidade. No teste de flexão em cantiléver (45 graus), foram realizadas duas avaliações, com cargas aplicadas, em D3 e D6, para cada grupo. Resultados: a comparação das cargas aplicadas em D3 e D6 nos instrumentos RaCe com diferentes conicidades mostrou valores de carga máxima significativamente diferentes para flexionar os instrumentos: D3 < D6, com a flexibilidade em D3 maior do que em D6. A comparação das cargas aplicadas em D3 nos três grupos revelou diferenças significativas entre os grupos (p < 0,0001), enquanto o teste Student-Newman-Keuls (SNK) mostrou diferenças de flexibilidade entre os três grupos: 0,06 < 0,04 < 0,02mm/mm. O mesmo resultado foi encontrado na comparação da força aplicada em D6. Conclusões: a flexibilidade do instrumento aumenta com a redução da conicidade (p < 0,05) e diminui com o aumento no diâmetro do eixo helicoidal (p < 0,05).


Subject(s)
Analysis of Variance , Dental Instruments/statistics & numerical data , Endodontics/instrumentation , Nickel/chemistry , Pliability , Titanium/chemistry
15.
Rev. CEFAC ; 18(6): 1359-1369, nov.-dez. 2016. tab
Article in Portuguese | LILACS | ID: biblio-842577

ABSTRACT

RESUMO Objetivo: identificar a associação entre hábito alimentar e desenvolvimento da fala em crianças pré-escolares. Métodos: estudo do tipo caso-controle, com amostra constituída por 273 crianças matriculadas nos Centros Municipais de Educação Infantil da cidade do Recife. Foi pesquisada a associação do desfecho com variáveis referentes a características socioeconômicas, hábitos de sucção nutritiva e não nutritiva e desenvolvimento do sistema estomatognático. Foram utilizados os softwares STATA/SE 9.0 e Excel 2007 para calcular a medida de risco, OddsRatio, o intervalo de confiança de 95% e o valor de p≤0,05. Para verificar a existência de associação, aplicou-se o teste qui-quadrado para variáveis categóricas. Resultados: no que se refere às alterações de fala, verificou-se associação significante no sexo masculino. Já os hábitos de sucção não se associaram significantemente com o desfecho estudado. Com relação ao sistema estomatognático, registra-se associação significante às alterações de fala, principalmente no que concerne à postura habitual de lábios e língua, assim como com a presença de oclusopatias. Não houve associação significante entre a variável de consistência alimentar e o evento estudado. Conclusão: a consistência alimentar demonstrou associação significante com variáveis que impactam na fisiologia adequada do sistema estomatognático, em termos de órgãos fonoarticulatórios e desempenho de funções, podendo-se inferir que padrão alimentar e fala constituem ponto de convergência na saúde infantil.


ABSTRACT Purpose: to identify the association between dietary habits and speech development in preschool children. Methods: case-control study, with sample constituted of 273 children enrolled in Municipal Daycare Centers in Recife. It was researched the association of outcome with the variables related to socioeconomic characteristics, nutritive and not nutritious sucking habits and development of the stomatognathic system. We used the software STATA/SE 9.0 and Excel 2007 to calculate the risk measure, Odds Ratio with a confidence interval of 95%, plus the value of p≤0.05. To verify the existence of association, it was adopted the chi-square test for categorical variables. Results: concerning the speech disorders, it was verified significant association in males. Yet, sucking habits were not significantly associated with the outcome studied. Regarding the stomatognathic system, it was registered significant association on speech disorders, especially regarding the habitual posture of the lips and tongue, as well as the presence of malocclusion. There was no significant association between food consistency and the variable studied event. Conclusion: the food consistency demonstrated a significant association with variables that impact on the proper physiology of the stomatognathic system, in terms of phono-articulatory organs and function performance, can be inferred that eating patterns and speech constitute a convergence point in child health.

16.
Rev. bras. odontol ; 73(3): 180-185, Jul.-Set. 2016. ilus, tab
Article in Portuguese | LILACS | ID: biblio-844026

ABSTRACT

Objetivo: O presente trabalho teve o objetivo de determinar as dimensões e verificar se os instrumentos X1, X2 e X3 atendem as recomendações da norma ANSI/ ADA nº 101 e se os cones de guta-percha F1, F2 e F3 atendem a norma ANSI/ADA nº 78. Material e Métodos: Os resultados dos instrumentos foram comparados com as dimensões dos cones de guta-percha. Foram utilizados 10 instrumentos e 10 cones de cada tipo. As imagens para análise micromorfométrica foram obtidas com uma lupa Opticam e as medidas determinadas com o software TSView versão 7.2.1.7. Os diâmetros em D3, D6 e D9 reais foram comparados com os nominais pelo teste t-student. Os diâmetros dos instrumentos em D3, D6 e D9 foram comparados com os dos cones pelo teste Anova e complementados com teste de comparações múltiplas SNK. Todos os testes adotaram nível de significância α=5%. Resultados: Os resultados obtidos mostraram que há diferença estatisticamente significante entre as dimensões reais e nominais dos instrumentos (p < 0,05). O instrumento X3 apresentou diferença estatisticamente significante em relação ao cone F1 (p < 0,05), onde os valores do cone são menores do que os dos instrumentos. Conclusão: Dentro das limitações deste estudo pôde-se concluir que: os instrumentos X1 e os cones de guta-percha não atenderam as recomendações de suas normas. O cone F1 pode ser uma opção para obturação dos canais modelados com o instrumento X3, porém a termoplastificação se faz necessária.


Objective: The aim of the present study was to verify if the Protaper Next instruments X1, X2, and X3 and the Protaper Universal gutta-percha cones F1, F2, and F3 meet the ANSI/ADA 101 and 78 recommendations. Material and Methods: The instruments' dimensions were compared with those obtained by the gutta-percha cones. For this, ten instruments and ten cones of each type were used. Micromorphometric images were obtained and analyzed through a stereomicroscope (OptiCam) and measurements were obtained with TSView software, version 7.2.1.7. The D3, D6, and D9 diameters were compared with the nominal diameters using the Student's t-test. After this, the real diameters of the instruments D3, D6, and D9 were compared with the gutta-percha cone diameters by Anova supplemented with SNK test for multiple comparisons. A p ≤0.05 was considered significant. Results: The results showed statistically significant differences between the real diameter and nominal diameter of the instruments (p <0.05). The X3 instrument showed a statistically significant difference when compared to the F1 cone (p <0.05), and the cone values were lower than the instrument values. Conclusion: Within the limitations of this study, it can be concluded that: 1) the X1 instrument and the gutta-percha points did not meet the recommendations, and 2) the F1 cone can be an option for filling the modeled channels with the X3 instrument, but termoplastification is required.

17.
Rev. bras. odontol ; 73(3): 237-241, Jul.-Set. 2016. ilus
Article in Portuguese | LILACS | ID: biblio-844035

ABSTRACT

Objetivo: O objetivo do presente trabalho foi revisar as publicações prévias sobre o EndoSequence BC Sealer com o intuito de avaliar os resultados obtidos por este cimento em relação às suas propriedades biológicas e físico-químicas, analisando-se, assim, de forma mais consistente, diversos âmbitos de sua atuação e possíveis desfechos de seu uso clínico realizar uma revisão de literatura sobre este material. Material e Métodos: Uma busca extensiva na literatura foi realizada para identificação de todos os artigos publicados sobre o cimento EndoSequence BC Sealer, considerando-se estudos que avaliaram suas propriedades biológicas e físico-químicas. A estratégia de busca foi fundamentada no acesso às bases de dados PubMed e Bireme. Resultados: Trinta e dois artigos satisfizeram os critérios de inclusão e foram utilizados na presente revisão. Os artigos demonstraram que o cimento possui radiopacidade, escoamento, solubilidade e alteração dimensional adequadas. Além disso, o cimento possui atividade antimicrobiana e é biocompatível. Conclusão: A avaliação dos trabalhos prévios do EndoSequence BC Sealer permite concluir que o cimento EndoSequence BC Sealer demonstrou performance satisfatória quanto as propriedades necessárias para um material obturador endodôntico.


Objective: The aim of this study was to review the previous publications of the EndoSequence BC Sealer in order to evaluate the results obtained using this sealer with regards to its biological and physicochemical properties; therefore, analyzing several areas of its performance and possible outcomes of its clinical use in a more reliable way. Material and Methods: A search of the literature was performed for the identification of all published articles using the EndoSequence BC Sealer, considering studies that evaluated its biological and physicochemical properties. The strategy of the search was based on access to the PubMed and Bireme databases. Results: Thirty-two manuscripts met the inclusion criteria and were used in this review. These manuscripts demonstrated that the sealer has adequate radiopacity, flow, solubility, and dimensional changes. Furthermore, the sealer has antimicrobial activity and is biocompatible. Conclusion: A review of the relevant literature suggests that the EndoSequence BC Sealer has demonstrated satisfactory performance in some important properties for a root canal sealer

18.
Dent. press endod ; 6(2): 28-33, May-Aug. 2016. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-846970

ABSTRACT

Objetivo: avaliar a composição semiquantitativa, a exibilidade e a microdureza de instrumentos endodônticos de ligas com NiTi convencional e com memória controlada (CM). E também avaliar a in uência da rotação contínua e do movimento reciprocante na resistência dos instrumentos submetidos à fadiga cíclica. Métodos: os instrumentos Hy ex CM 40/0.04 e RaCe 40/0.04 foram submetidos aos testes de exibilidade, EDS e microdureza. A fadiga cíclica estática foi avaliada em rotação contínua, 150° horá- rio/30° anti-horário; 75° horário/15° anti-horário. Resultados: o Hy ex CM é mais exível que o RaCe (p < 0,05), mas não houve diferença signi cativa quanto à microdureza (p>0,05). O RaCe tem 55,7%wt Ni e 44,3%wt Ti, enquanto o Hy ex CM tem 50,81%wt Ni e 42,28%wt Ti. O movimento reciprocante aumentou signi cativamente a resistência à fadiga cíclica dos instrumentos avaliados, quando comparado à rotação contínua (p < 0,05). O Hy ex CM foi signi cativamente mais resistente no movimento reciprocante de menor ângulo, quando comparado com o de maior ângulo (p<0,05), enquanto não houve diferença para o RaCe (p > 0,05). O Hy ex CM apresentou maior resistência à fadiga do que o RaCe, em todos os movimentos avaliados (p < 0,05). Conclusão: o Hy ex CM tem maior exibilidade e menor percentual de Ni quando comparado ao RaCe, mas ambas apresentaram microdureza similar. O Hy ex CM teve resistência à fadiga cíclica maior do que o RaCe, em todos os movimentos. Os dois instrumentos tiveram maior resistência à fadiga no movimento reciprocante do que na rotação contínua. A menor angulação do movimento reciprocante promoveu maior resistência à fadiga, quando comparada com a de maior amplitude.


Subject(s)
Humans , Fatigue , Microscopy, Electron, Scanning , Nickel , Chemical Phenomena , Rotation , Titanium
19.
Article in Portuguese | LILACS | ID: lil-724196

ABSTRACT

Objetivo: Avaliar o comportamento mecânico de instrumentos endodônticos de NiTi K3 (Sybron Endo,Orange, CA), fabricados convencionalmente e K3XF(Sybron Endo, Orange, CA), submetidos a tratamento térmico na fabricaçÆo.Métodos: Foram utilizados 20 instrumentos K3 e K3XF com D0 0,25 mm, conicidade 0,06 mm/mm e 25 mm de comprimento. Para estandardizaçÆo, dez instrumentos de cada tipo foram examinados sob estereomicroscópio e dois instrumentos (K3 e K3XF) tiveram suas secçães transversais analisadas em microscópio eletrônico de varredura (MEV). A flexibilidade e resistência à fratura foram avaliadas em ensaio de flexÆo em 45° e em teste estático de fadiga, respectivamente. Dez instrumentos K3 e K3XF foram utilizados em cada teste, registrando-se os valores da carga flexural e o número de ciclos para ocorrer a fratura (NCF). Para análise estatística empregou-se o teste t de Student. Os instrumentos fraturados foram analisados em MEV. Resultados: A carga flexural foi significativamente maior para as limas K3 do que para as K3XF (p˂0,05), apresentando, respectivamente, os valores de 713,5 g e 536,4 g. O NCF foi significativamente maior para os instrumentos K3XF em comparaçÆo com as limas K3 (p˂0,05). A análise das superfícies fraturadas em MEV revelou características morfológicas do tipo dúctil para ambos os instrumentos e ausência de deformaçÆo plástica. ConclusÆo: Os instrumentos de NiTi submetidos a tratamento térmico apresentaram os menores valores de força para serem flexionados em 45° e os mais elevado valores de NCF. Desse modo, pode-se inferir que os instrumentos submetidos ao tratamento térmico diferenciado (K3XF) sÆo mais flexíveis e mais resistentes à fratura por fadiga do que os instrumentos K3, fabricados convencionalmente...


Objective: To evaluate the mechanical behavior of K3 NiTi endodontic instruments (Sybron Endo, Orange, CA, USA) with conventional manufacturing or subjected to a thermal treatment during manufacturing (K3XF instruments; Sybron Endo). Methods: Twenty K3 and K3XF instruments with D0 0.25 mm, 0.06 mm/mm taper and 25 mm length were used. For standardizing purposes, 10 instruments of each type were examined by a stereomicroscope and two instruments (K3 and K3FX) had their cross-sections analyzed by scanning electron microscopy (SEM). Flexibility and fracture strength were evaluated by 45° bending test and static fatigue test, respectively. Ten K3 and K3FX instruments were used for each test, obtaining the flexural load values and the number of cycles to failure (NCF). Student?s t test was used for statistical analysis. The fractured instruments were examined by SEM. Results: The flexural load was significantly greater for the K3 than for the K3FX (p<0.05) instruments, 713.3 g and 536.4 g, respectively. The NCF was significantly greater for the K3FX than for the K3 instruments (p<0.05). SEM analysis of the fractured surfaces revealed ductile-type morphological characteristics for both types of instruments and absence of plastic deformity.Conclusion: NiTi instruments subjected to thermal treatment presented lower flexural strength values when subjected to 45º bending and greater NCF values. It may be assumed that the instruments subjected to a special thermal treatment during the manufacturing process (K3FX) are more flexible and more resistant to fatigue fracture than the conventional K3 instruments...


Subject(s)
Humans , Dental Instruments , Nickel , Materials Science , Titanium , Root Canal Therapy , Endodontics/methods
20.
Rev. bras. odontol ; 69(2): 170-173, Jul.-Dez. 2012. tab
Article in Portuguese | LILACS | ID: lil-720334

ABSTRACT

Esse estudo avaliou e comparou a resistência em flexão de instrumentos endodônticos mecanizados obtidos de fios metálicos de níquel-titânio (NiTi) convencional e M-wire. Para avaliar a resistência em flexão empregou-se o ensaio mecânico de flexão em cantilever. A flexibilidade em flexão de um instrumento endodôntico depende da composição química e do tratamento termomecânico da liga metálica, assim como, da geometria da seção reta transversal da haste cônica helicoidal do instrumento endodôntico. Os resultados obtidos revelaram que os instrumentos Profile Vortex, fabricados a partir de fios metálicos de NiTi denominados M-wire, apresentaram a maior resistência em flexão (menor flexibilidade). Os instrumentos RaCe, produzidos a partir de fios metálicos de NiTi convencional, apresentaram a menor resistência em flexão (maior flexibilidade).


This study evaluated and compared the bending resistance of rotary endodontic instruments made of conventional nickel-titanium (NiTi) and M-wire by means of cantilever bending test. The flexibility of an endodontic instrument depends on its chemical composition and the thermo mechanical treatment of the alloy, as well as on its cross-sectional geometry on the helical shaft of the endodontic instrument. The results showed that the Profile Vortex instruments, made from NiTi wires called M-wire, had the greatest bending resistance (lowest flexibility), while RaCe instruments, produced from conventional NiTi wires showed the lowest bending resistance (greatest flexibility) among the instruments tested.


Subject(s)
Root Canal Therapy/instrumentation , Flexural Strength
SELECTION OF CITATIONS